Hydraulic Motor replacement for Danfoss OMP series 50/63/80/100/160/200/315cc,2-Bolt Mounting Flange ,G1/2 NPT Ports

  • Double needle bearing can bear higher radial force,with more Concentricity that can help smooth running under the high speed condition;
  • High quality oil seal lead to longer service life;
  • Shaft seal can bear high pressure of back and the motot can be used in parallel or in series;
  • Special design in the driver-linker and prolong operating life;
  • Special design for distribution system can meet the requirement of low noise of unit;
  • Integration of efficiency and economy to environment-friendly;
  • Product MOQ 100 PCS/ order
  • Compact volume and easy installation;
Share to

Description

Hydraulic Motor OMP/BMP series

BM1/OMP series motor are small volume, economical type, which is designed with shaft distribution flow, which adapt the geroler gear set design and provide compact volume, provide reliable and smooth operation with low speed and high torque.

 

Ordering Information

Product NO

Displacement(CCM)

Mounting Flange(MM)

Shaft(MM)

Port Size

Drain Port

Shaft end thread

Mounting holes

Oil Port shape

Parallel key widthMM

BMP/OMP

50/63/80/100/160/200/315

82.5

25

G1/2

G1/4

M8

2

S

8

 

Characteristic Features

1.Double needle bearing can bear higher radial force,with more Concentricity that can help smooth running under the high speed condition;

2.High quality oil seal lead to longer service life;

3.Shaft seal can bear high pressure of back and the motot can be used in parallel or in series;

4.Special design in the driver-linker and prolong operating life;

5.Special design for distribution system can meet the requirement of low noise of unit;

6.Integration of efficiency and economy to environment-friendly;

7.Compact volume and easy installation;

 

Main Specification

 

TYPE

BM1

BM1

BM1

BM1

BM1

BM1

BM1

BM1

BM1

BM1

OMP

OMP

OMP

OMP

OMP

OMP

OMP

OMP

OMP

OMP

Displacement(ml/r)

50

63

80

100

125

160

200

250

315

400

Flow

(LPM)

Continuous

45

45

60

60

60

60

60

60

60

60

Intermittent

50

50

75

75

75

75

75

75

75

75

Speed

(RPM)

Continuous

879

720

740

589

475

370

296

237

189

149

Intermittent

975

755

827

673

594

463

370

297

236

185

Pressure

(MPA)

Continuous

12.5

12.5

12.5

12.5

12.5

12.5

11

11

11

10

Intermittent

16.5

16.5

16.5

16.5

16.5

16.5

16.5

14

12.5

10.5

Torque

(N*.m)

Continuous

81

101

129

161

202

245

286

360

406

435

Intermittent

108

134

171

213

268

342

390

456

505

533

1. Continuous pressure:Max.value of operating motor continuously.

2.Intermittent pressure:Max.value of operating motor in 6 seconds per minute .

3.Peak pressure:Max.value of operating motor in 0.6 second per minute.

4.The optimum operating situation should be at the 1/3-2/3 of the continuous operating situation.

 

Replaceable Orbital Motors Cross Reference Table

FY

 

DANFOSS

M+S

EATON

ROSS

WHITE

 

PARKER

SAM

BOSCH

HYDRAULIC

HYDRAULIC

CHAR LYNN

TRW

CROSS

BREVINI

RECROTH

BMM

OMM

MM   MLHK

J SERIES

 

 

 

BGM

MGX

BM1/BMP

OMP DH

MP    HP

H SERIES

MF MG

WP RS

TC TE TB

BG

MGP GXP

BM2/BMR

OMR DS  OMEW

MR HR MLHRW,RW

S,T SERIES

W SERIES

MB

WR RE

TF

BR

MGR GMR

BM4/BMH

OMH

MH MLHH HW HWF

 

ME

RE

TG

 

 

BM5/BMS

OMS

MS MSY MLHS

2000 SERIES

ME

RE

TG

HPR

MGS GMS

BM6/BMT

OMT TMT

MT MLHT MTM

6000 SERIES

MJ

 

 

HT

MGT,GMT

BMV

OMV

MV MLHV

10000 SERIES

 

 

 

 

MGV GMV

 

Usage Guide

1.BM Series motors are designed as low speed high torque and low weight type motors.

2.A simultaneous max,speed and max.pressure is not recommended.

3.Can be used in parallel or in series.Case drain line is necessary when back pressure is over 5 Mpa.

4.The optimum operating situation should be at the 1/3-2/3 of the continuous operating situation.

5.Make sure the motor is always filled with oil before operating.

6.Max.operating temperature:80℃.

7.Recommended fluid:Anti-wear type of hydraulic oil.Viscosity recommended 37-73cst.Filtration:ISO19/16.

 

Hydraulic Motor replacement for Danfoss OMP series 50/63/80/100/160/200/315cc,2-Bolt Mounting Flange ,G1/2 NPT Ports

 

Notes:

The products you buy from us with 12 months quality warrenty,during the guarantee period we will replace products free of charge or refund your money in full.

Download

Ccontact us

+86-23-68417490
+86-18716267125
Room 713,Build No.7 Gov Office LiangLu-CunTan Free Trade Port Area ChongQing,China